Classes of Fire Explained: A, B, C, D, F and Electrical

Quick Answer

In the UK there are five classes of fire under BS EN 2: Class A (solids such as wood and paper), Class B (flammable liquids), Class C (flammable gases), Class D (metals) and Class F (cooking oils and fats). Electrical fires are not a separate class, but they need their own choice of extinguisher, usually CO2.

Fires are classified by what is burning, because the fuel decides which extinguisher will work and which will make things worse. This guide covers each class with workplace examples, the right and wrong extinguishers, how electrical fires fit in, and why UK and US classes use different letters.

Can your staff pick the right extinguisher under pressure? Fire Awareness Training: half a day at your site, covering classes of fire and the right extinguisher for each, with an optional practical where every delegate discharges an extinguisher. Ask about dates →

What are the 5 classes of fire?

The five classes are A, B, C, D and F, set out in the European standard BS EN 2, Classification of fires. The standard groups fires by the material that is burning, and the same five classes appear in the government’s fire risk assessment guidance for offices and shops.

ClassWhat is burningWorkplace examplesSuitable extinguishers
ASolids, usually organicWood, paper, cardboard, textiles, many plasticsWater, foam, dry powder, water mist
BFlammable liquids and liquefiable solidsPetrol, diesel, oils, solvents, paints, waxesFoam, CO2, dry powder, water mist
CFlammable gasesPropane, butane, natural gas, acetyleneDry powder, after isolating the gas supply; seek specialist advice
DMetalsMagnesium, aluminium swarf and powder, lithium metal, titaniumSpecialist Class D powder or dry sand only; seek specialist advice
FCooking oils and fatsDeep fat fryers, chip pans, commercial kitchensWet chemical, fire blanket for small pan fires
Electrical (not a BS EN 2 class)Live electrical equipmentComputers, switchgear, distribution boards, appliancesCO2, dry powder, water mist; isolate the power if safe

Source: BS EN 2; London Fire Brigade Guidance Note 08 (Rev 20, 2025); Warwickshire Fire and Rescue Service; HM Government, Fire safety risk assessment: offices and shops.

Class A fires: solid materials

Class A fires involve ordinary solid combustibles. They are the most common type in offices, shops, warehouses and schools, because paper, cardboard, furniture and packaging are everywhere.

Water is the traditional Class A agent. It soaks into the material and cools it below the point where it will keep burning. Foam and dry powder also work on Class A, as does water mist. CO2 is not listed for Class A fires because it does little to cool the burning material, so the fire can reignite once the gas clears.

Extinguishers that work on Class A carry an “A” rating such as 13A. The number reflects the size of test fire it put out, so a higher number means more firefighting capacity.

Class B fires: flammable liquids

Class B covers flammable liquids and solids that melt into liquids when heated, such as waxes and some plastics. Workshops, vehicle maintenance areas, print rooms, cleaning stores and anywhere that uses solvents or fuels can have a Class B risk.

Do not use a standard water extinguisher on a burning liquid. The water can spread the liquid and the fire with it. (Some water extinguishers with additives carry a B rating as well; the label will say so.) Foam smothers the surface and seals in the vapours, CO2 displaces the oxygen, and dry powder knocks the flames down. Class B ratings look like 34B or 55B.

Where flammable liquids or vapours could form an explosive atmosphere, the Dangerous Substances and Explosive Atmospheres Regulations also apply. Our guide to the DSEAR regulations explains what that means.

Class C fires: flammable gases

Class C fires involve gases such as propane, butane, natural gas and acetylene. The first and most effective action is to shut off the gas supply, but only if that can be done safely.

Putting out a gas flame while the gas is still escaping can be more dangerous than the flame itself, because unburnt gas can build up and then ignite explosively. Dry powder extinguishers are rated for Class C, but London Fire Brigade guidance advises seeking specialist advice for Class C risks. If in doubt, evacuate and call 999.

Class D fires: combustible metals

Class D fires involve metals such as magnesium, aluminium in powder or swarf form, titanium and lithium metal. They are mostly found in specialist manufacturing, machining and laboratories.

Metal fires burn extremely hot and can react badly with ordinary agents, including water. Only a specialist Class D powder (London Fire Brigade lists its colour code as signal violet) or dry sand should be used, and the choice should come from specialist advice based on the specific metal. Standard dry powder extinguishers are not suitable.

Class F fires: cooking oils and fats

Class F fires involve cooking oils and fats at very high temperatures, typically in deep fat fryers in commercial kitchens. Cooking oil fires have their own class because they behave differently from other liquid fires, and need their own type of extinguisher. Government fire safety guidance describes Class F extinguishers as particularly suitable for commercial kitchens with deep-fat fryers, and says foam extinguishers are not suitable for deep-fat fryers or chip pans.

Wet chemical extinguishers are designed for Class F. The agent bonds with the burning fat or oil, smothering the fire and cooling it. A fire blanket can smother a small pan fire. Never use water: Essex County Fire and Rescue Service warns never to throw water on hot or burning oil. Turn off the heat if it is safe and call 999.

Are electrical fires a class of fire?

No. BS EN 2 states that it does not define a particular class of fire involving an electrical risk. Electricity is a source of ignition rather than a fuel, and once the power is off, the fire is usually a Class A or Class B fire.

While the equipment is live, though, the extinguisher must not conduct electricity back to the user. That rules out water and foam. CO2 is the usual choice: Warwickshire Fire and Rescue Service lists it for computer equipment and other electrical appliances. Dry powder also works, and London Fire Brigade lists water mist as suitable for electrical fires. Isolate the power first if you can do so safely. This is why extinguisher charts and signs often show “electrical” as an extra category, even though the standard does not.

Why do UK and US classes of fire differ?

The US uses a different system, set by the National Fire Protection Association, with five classes: A, B, C, D and K. The letters do not line up with BS EN 2, which causes confusion when people read American websites or safety data sheets.

FuelUK and Europe (BS EN 2)United States (NFPA)
Ordinary solidsClass AClass A
Flammable liquidsClass BClass B
Flammable gasesClass CGrouped with Class B
Electrical equipmentNo class (often shown as “electrical”)Class C
MetalsClass DClass D
Cooking oils and fatsClass FClass K

If you work in the UK, use the BS EN 2 letters. An extinguisher marked for “Class C” in the UK is rated for gas fires, not electrical ones.

Your fire risk assessment should identify which classes of fire could occur in each area, and the extinguishers provided should match. Under Article 13 of the Regulatory Reform (Fire Safety) Order 2005, the responsible person must, where necessary, make sure the premises are equipped with appropriate firefighting equipment, and that any manual equipment is easily accessible, simple to use and indicated by signs.

In practice that means water or foam for general areas, CO2 near electrical equipment and server rooms, wet chemical in kitchens with fryers, and specialist advice for gas and metal risks. Our guide to fire extinguisher colours and types shows how to tell them apart, and the fire triangle explains how each one puts a fire out.

Some hazards should not be tackled at all. Warwickshire Fire and Rescue Service and the government guidance both advise that it is not safe to fight fires involving aerosols with extinguishers.

Frequently asked questions

How many classes of fire are there in the UK?

Five, under BS EN 2: Class A (solids), Class B (flammable liquids), Class C (flammable gases), Class D (metals) and Class F (cooking oils and fats). Electrical fires are not a separate class, but they are often shown as a sixth category on extinguisher charts.

Which class of fire involves electrical equipment?

None. BS EN 2 does not define a class for electrical fires, because electricity is an ignition source rather than a fuel. Use a CO2 extinguisher on live electrical equipment, or dry powder or water mist where they are provided, and never use water or foam.

What is a Class F fire?

A fire involving cooking oils and fats, usually in a deep fat fryer. Use a wet chemical extinguisher, or a fire blanket on a small pan fire. Never use water on burning oil.

What is the difference between Class B and Class C fires?

Class B fires involve flammable liquids such as petrol, oils and solvents. Class C fires involve flammable gases such as propane, butane and natural gas. For a gas fire, isolating the supply safely is the first priority.

What extinguisher is used on Class D fires?

Only a specialist Class D powder extinguisher or dry sand, chosen with specialist advice for the specific metal. Water and standard extinguishers can make metal fires far worse.

What is the most common class of fire in workplaces?

Class A, because paper, cardboard, wood, textiles and furniture are present in almost every workplace. For the Class A risk, government guidance says one water-based extinguisher for about every 200 square metres of floor space, with at least two per floor, will normally be adequate.

Why is it called Class K in America?

The US uses the NFPA classification, where cooking oil fires are Class K and Class C means electrical fires. In the UK and Europe, BS EN 2 uses Class F for cooking oils and Class C for gases.

Where to learn more

Talk to KeyOstas

We deliver fire awareness and fire marshal training at your site, using the fire risks and extinguishers in your own premises.

Send an enquiry or call +44 (0)330 056 9534.